MISAN PME-114 SERIES SHELL&TUBE HEAT EXCHANGER

DIMENSION TABLE
MISAN
Model
Oil
d
Water
d
D
mm
f
mm
e
mm
L
mm
PME-114-1 1 1/4" 3/4" 114 165 500 740
PME-114-2 1 1/4" 3/4" 114 165 700 940
PME-114-3 1 1/4" 3/4" 114 165 900 1140
PME-114-4 1 1/4" 3/4" 114 165 1100 1340
Dimensions are not binding, Misan has the right to modify dimensions




Tech Data is not binding
Capacity With Optimal Oil Flow
Tube Side:Water
Shell Side:ISO 46 grade oil
water inlet:20°C
Tech Data is not binding
Tube Side:Water
Shell Side:ISO 46 grade oil
LMTD:25°C
Disclaimer: Oil Flow may exceed the maximum suggested value











Misan PME-114 series Shell and Tube Heat Exchangers are designed for Hydraulic applications upto 50kW and can be modified for Marine applications.
PME-114 series are structured as "Floating Head" and this structure provides higher resistance against thermal stresses by permitting the tubes to expand/shrink due to temperature changes.
Tubes to tube sheet leakage connection is utilized with tube expanding method.
The Capacity and Pressure Drop tables are developed for the 1 Shell pass- 2 Tube Pass(1-2 configuration) with Copper(Cu) Tubes based on the most accepted method-Bell-Delaware method. Internal design and material can be modified to match the requirements. For Marine applications CuNiFe or Cupro-Nickel(%90-%10) tubes are used, and the capacity can be accepted equal to the tables.
Fouling effect is neglected in the charts and velocity of liquids are accepted in ideal values. We welcome you to consult our engineers to specify the most optimal sizing for your application.
This product comes with "1 year" product warranty. Please consult Misan for the warranty terms.

Material Table
Material Covers Tubes Shell
Standard
Application
Cast Iron Copper Steel
Marine
Application
Bronze Cupro-Nickel Steel

Viscosity Correction
Oil Grade Grade 32 Grade 46 Grade 68 Grade 96
Correction
Factor
X 1 X X

Inlet Temperature Correction
Temperature °C 20 °C 25 °C 30 °C 35 °C 40 °C
Correction
Factor
1 1.05 1.10 1.15 1.20